Operating Instructions
for the
AGS 125 Greasing Unit
The AGS 125 unit is easy to
install and use. Take advantage of the electronically monitored greasing system.

 |
 |
 |
 |
| Pre-grease bearing with
hand grease gun. |
Remove greasing nipple
from bearing with wrench. |
Reduction adapters from G¼
to M6x1; M8x1, G? |
Screw on AGS unit with standard
thread G¼ |
 |
 |
 |
 |
|
Remove protective lid and activate
greasing unit. |
Set grease dosage with dip
switch combinations. |
When switch 7 activated indicator light
blinks approx. every 20 sec. |
To turn OFF, click all switches to bottom
position. |
PRESSURE BUILD-UP
After activation, greasing units
require a central set-up time for pressure to develop.
Batteries start an
electro-pneumatic reaction and internal pressure builds up behind the piston.
Greasing starts after correct pressure is reached. Pressure will be maintained
even if the unit is switched off for a time. When the unit is switched on again,
greasing starts immediately due to existing pressure. Simply set the desired
running time and mount the greasing unit. The following table indicated the
build-up times.
| Time Setting in months |
1 |
2 |
3 |
6 |
12 |
18 |
| Dip switch |
1 |
2 |
3 |
4 |
5 |
6 |
| Pressure build-up in
days |
1 |
2 |
3 |
6 |
10 |
14 |
QUICK OPTION
If immediate greasing is desired,
set all dip switches to the ON position. Pressure build-up time will be
approximately 6-8 hours. Afterwards, click switches to the desired settings.
(See Lubrication Options table below.)
With the AGS 125 Lubricator, there
are 25 different settings possible. The table below sets out the options you can
use to fit your specific needs in terms of dosage rate and length of greasing period.
|
Dip Switch
Positions |
Daily Greasing
Rate |
Days Until Empty |
|
No. 7
switch for ON. Indicator light blinks in short intervals. |
|
6 = 18 M |
0.175 cc |
18 months |
|
5 = 12 M |
0.35 cc |
1 year |
|
4 = 6 M |
0.70 cc |
6 months |
|
3 = 3 M |
1.30 cc |
3 months |
|
2 = 2 M |
2.10 cc |
2 months |
|
1 = 1 M |
4.00 cc |
1 month |
|
All switches
activated |
9.00 cc |
14 days |
|
Combination Settings: |
|
5 + 4 |
1.05 cc |
121 days |
|
5 + 3 |
1.74 cc |
71 days |
|
4 + 3 |
2.08 cc |
57 days |
|
5 + 4 + 3 |
2.35 cc |
51 days |
|
5 + 2 |
2.45 cc |
52 days |
|
4 + 2 |
2.60 cc |
45 days |
|
3 + 2 |
3.48 cc |
35 days |
|
5 + 3 + 2 |
3.83 cc |
28 days |
|
4 + 3 + 2 |
4.16 cc |
30 days |
|
5 + 4 + 3 + 2 |
4.53 cc |
27 days |
|
4 + 1 |
4.80 cc |
24 days |
|
3 + 1 |
5.56 cc |
23.5 days |
|
2 + 1 |
6.26 cc |
20 days |
|
5 + 2 + 1 |
6.61 cc |
19 days |
|
3 + 2 + 1 |
7.65 cc |
17 days |
|
5 + 3 + 2 + 1 |
8.00 cc |
16 days |
|
4 + 3 + 2 + 1 |
8.33 cc |
15 days |
| 5 + 4 + 3 + 2 + 1
|
8.70 cc |
14.5 days |
125+475 Units