Technical Tips & General Operation Info
Greater benefits with the self-contained automatic greasing systems
| INSTALLATION INSTRUCTIONS |
![]() |
![]() |
![]() |
![]() |
Pre-grease bearing with hand grease gun |
Remove greasing nipple from bearing with wrench |
Reduction adapters from G1/4 to M6x1; M8x1; G1/8 |
Screw on AGS unit with standard thread G1/4 |
![]() |
![]() |
![]() |
![]() |
Remove protective lid and activate greasing unit |
Set grease dosage with dip switch combinations |
When switch 7 is activated indicator light blinks approx every 20 sec |
To turn OFF, slick all switches to bottom position |
| PRESSURE BUILD-UP |
After activation, greasing units require a certain set-up time for pressure to develop. Batteries start an electro-pneumatic reaction and internal pressure builds up behind the piston. Greasing starts after the correct pressure is reached. Pressure will be maintained even if the unit is switched off for a time. When the unit is switched on again, greasing starts immediately due to existing pressure. Simply set the desired running time and mount the greasing unit. The following table indicated the build-up times.
| Time setting in months | 1 |
2 |
3 |
6 |
12 |
18 |
| Dip switch | 1 |
2 |
3 |
4 |
5 |
6 |
| Pressure build-up in days | 1 |
2 |
3 |
6 |
10 |
14 |
QUICK OPTION
If immediate greasing is desired, set all dip switches to the ON position. Pressure build-up time will e approximately 6-8 hours. Afterwards, click switches to the desired settings (see Lubrication Options table below).
| LUBRICATION OPTIONS AND THE RELATED SWITCH COMBINATIONS |
With the AGS 125 lubricator, there are 25 different settings possible. The Table below sets out the options you can use to fit your specific needs in terms of rate and length of greasing period.
Dip Switch Positions |
Daily Greasing Rate |
Days Until Empty |
The no. 7 switch is for ON. Indicator light blinks in short intervals. |
||
6 = 18 M |
0.175 cc |
18 months |
5 = 12 M |
0.35 cc |
1 year |
4 = 6 M |
0.70 cc |
6 months |
3 = 3 M |
1.30 cc |
3 months |
2 = 2 M |
2.10 cc |
2 months |
1 = 1 M |
4.00 cc |
1 month |
All switches activated |
9.00 cc |
14 days |
Combination Settings
|
||
5 + 4 |
1.05 cc |
121 days |
5 + 3 |
1.74 cc |
71 days |
4 + 3 |
2.08 cc |
57 days |
5 + 4 + 3 |
2.35 cc |
51 days |
5 + 2 |
2.45 cc |
52 days |
4 + 2 |
2.60 cc |
45 days |
3 + 2 |
3.48 cc |
35 days |
5 + 3 + 2 |
3.83 cc |
28 days |
4 + 3 + 2 |
4.16 cc |
30 days |
5 +4 + 3 + 2 |
4.53 cc |
27 days |
4 + 1 |
4.80 cc |
24 days |
3 + 1 |
5.56 cc |
23.5 days |
2 + 1 |
6.26 cc |
20 days |
5 + 2 + 1 |
6.61 cc |
19 days |
3 + 2 + 1 |
7.65 cc |
17 days |
5 + 3 + 2 + 1 |
8.00 cc |
16 days |
4 + 3 + 2 + 1 |
8.33 cc |
15 days |
5 +4 + 3 + 2 + 1 |
8.70 cc |
14.5 days |