Installation
Instructions for the
AGS Low-Cost
Lubricator
Follow these 4 simple steps for
trouble-free AGS Low-Cost Lubrication operation.

-
Screw in the starter cap by hand. (You will hear
the seals break while doing this.) Use a screw driver or similar tool to
tighten firmly (picture left).
-
Record change-over date.
-
Pre-grease bearing before first installation.
-
Install AGS Low-Cost Lubricator hand tight into
grease point.
Do NOT remove the AGS Low-Cost
Lubricator until the change-over date!
-
AGS Low-Cost Lubricator is designed to operate at
an average environmental temperature of 77ºF (25ºC). Refer to
Technical Tips
for information about using the AGS Low-Cost Lubricator at different
temperatures. Allow 8-40 hours for operation to begin, depending on the
Low-Cost Lubricator type.
-
If the AGS Low-Cost Lubricator is to be installed
with extension hoses, use a minimum 8 mm D tubing. The maximum recommended
length is 5 feet (1.5 meters).
-
Do not screw the starter cap into the AGS Low-Cost
Lubricator until ready to activate the unit.
-
Wear protective gloves when activating the AGS
Low-Cost Lubricator.
-
Dispose of used unit in the industrial waste bin.
COLOR CODES: The color of the
activator in the base of the AGS Low-Cost Lubricator and the starter cap must
match. These indicate the type of unit being used.
|
Base Color |
Duration |
Type |
| White |
1 month unit |
01W |
| Blue |
3 months unit |
03B |
| Red |
6 months unit |
06R |
| Grey |
12 months unit |
12G |